Battery Storage
  General Storage Conditions:
  The battery should be stored under the following conditions
(1)Low humidity
(2)5 to 104℉(-15 to 40℃)
(3)Clean and avoid direct sunlight.
 Capacity after long term storage
 After long term storage, all batteries deliver less than rated capacity on cycle. In cyclic application, Full capacity may be obtained through several charge/discharge cycles; typically 3-5 cycles.
 Refresh Charge
  When batteries are placed in extended storage, It is recommended that they receive a refresh charge at recommended intervals.
 Storage ambient:              Recommended interval
 Below 68℉(20℃)      :          12months
 68 to 86℉(20 to 30℃)   :          6months
 86 to 104℉(30 to 40℃)  :          3months

 